Zib-wounds #2769
Annotations
8 errors, 10 warnings, and 3 notices
Zib2020 QA:
resources/zib/zib-Burnwound.xml#L1
An ignored issue was provided, but the issue didn't occur (at zib-Burnwound)
|
Zib2020 QA:
resources/zib/zib-Wound.xml#L1
An ignored issue was provided, but the issue didn't occur (at zib-Wound)
|
Zib2020 QA:
resources/zib/zib-wounds.DateOfLastDressingChange.xml#L52
Unknown code '360541000146109' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000146104/version/20230331' (at StructureDefinition.differential.element[1].pattern.ofType(CodeableConcept).coding[0].code)
|
Zib2020 QA:
resources/zib/zib-wounds.WoundCharacteristics.xml#L1
An ignored issue was provided, but the issue didn't occur (at zib-wounds.WoundCharacteristics)
|
Zib2020 QA:
resources/zib/zib-Burnwound.Extent.xml#L42
Unknown code '360531000146101' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000146104/version/20230331' (at StructureDefinition.differential.element[1].pattern.ofType(CodeableConcept).coding[0].code)
|
Zib2020 QA:
resources/zib/zib-PressureUlcer.xml#L1
An ignored issue was provided, but the issue didn't occur (at zib-PressureUlcer)
|
Zib2020 QA:
resources/zib/zib-Wound.Drain.Product.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.19.2.7--20200901000000 is not a subset of binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.1.1--20200901000000 (at StructureDefinition)
|
Zib2020 QA:
resources/zib/zib-Wound.Drain.xml#L1
An ignored issue was provided, but the issue didn't occur (at zib-Wound.Drain)
|
Zib2020 QA:
resources/zib/zib-HearingFunction.HearingAid.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.11--20200901000000 could not be expanded (at StructureDefinition)
|
Zib2020 QA:
resources/zib/terminology/ValueSet-BrandwondSoortCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.4.3--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/ValueSet-WondSoortCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.2.4--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/ValueSet-DieptegraadCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.4.1--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/ValueSet-BrandwondLateraliteitCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.4.4--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/ValueSet-DecubitusCategorieCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.1.1--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/ValueSet-WondDrainTypeCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.2.7--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/WondRandCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.2.5--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/WondWeefselOncoUlcerCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.2.2--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/terminology/BrandwondLateraliteitCodelijst-2.16.840.1.113883.2.4.3.11.60.40.2.19.4.4--20200901000000.xml#L1
Constraint failed: dom-6: 'A resource should have narrative for robust management' (defined in http://hl7.org/fhir/StructureDefinition/DomainResource) (Best Practice Recommendation) (at ValueSet)
|
Zib2020 QA:
resources/zib/zib-PressureUlcer.xml#L49
The code '399912005' is valid but is not active (at StructureDefinition.differential.element[1].pattern.ofType(CodeableConcept).coding[0].code)
|
Zib2020 QA:
resources/nl-core/nl-core-Wound.Drain.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended (at StructureDefinition.snapshot.element[9])
|
Zib2020 QA:
resources/nl-core/nl-core-Wound.Drain.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended (at StructureDefinition.snapshot.element[13])
|
Loading