Skip to content

zib MultidisciplinaryTeamMeeting #1388

zib MultidisciplinaryTeamMeeting

zib MultidisciplinaryTeamMeeting #1388

Triggered via pull request July 25, 2023 07:06
Status Failure
Total duration 10m 30s
Artifacts

qa-all.yml

on: pull_request
Loose QA on the entire repo
10m 19s
Loose QA on the entire repo
Fit to window
Zoom out
Zoom in

Annotations

10 errors and 10 warnings
Loose QA on the entire repo: examples/nl-core-LaboratoryTestResult.Specimen-02.xml#L7
None of the codings provided are in the value set 'Monstermateriaal-en-Microorganisme-Codelijsten' (http://nictiz.nl/fhir/ValueSet/Monstermateriaal-en-Microorganisme-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://snomed.info/sct#87612001)
Loose QA on the entire repo: examples/nl-core-Encounter-01.xml#L8
Wrong Display Name 'Inpatient' for http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP - should be one of 1 choices: 'inpatient encounter' (for the language(s) 'en') for 'http://terminology.hl7.org/CodeSystem/v3-ActCode#IMP'
Loose QA on the entire repo: examples/nl-core-LaboratoryTestResult-01.xml#L22
None of the codings provided are in the value set 'TestCode-en-Onderzoek-Codelijsten' (http://nictiz.nl/fhir/ValueSet/TestCode-en-Onderzoek-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://loinc.org#2947-0)
Loose QA on the entire repo: examples/nl-core-HealthProfessional-Practitioner-01.xml#L68
None of the codings provided are in the value set 'LandCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.10--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = urn:iso:std:iso:3166#NL)
Loose QA on the entire repo: examples/nl-core-Patient-01.xml#L116
None of the codings provided are in the value set 'LandCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.10--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = urn:iso:std:iso:3166#NL)
Loose QA on the entire repo: examples/nl-core-LaboratoryTestResult-03.xml#L22
None of the codings provided are in the value set 'TestCode-en-Onderzoek-Codelijsten' (http://nictiz.nl/fhir/ValueSet/TestCode-en-Onderzoek-Codelijsten|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://loinc.org#22314-9)
Loose QA on the entire repo: examples/nl-core-Vaccination-event-02.xml#L8
None of the codings provided are in the value set 'ProductCodeCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.17--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://www.whocc.no/atc#J07BC02)
Loose QA on the entire repo: examples/nl-core-Alert-02.xml#L16
The code provided (http://snomed.info/sct#432415000) is not in the value set 'AlertNaamCodelijst' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.8.3.2--20200901000000|2020-09-01T00:00:00), and a code from this value set is required: Unable to check whether the code is in the value set http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.8.3.2--20200901000000|2020-09-01T00:00:00
Loose QA on the entire repo: examples/nl-core-TreatmentDirective2-01-RelatedPerson-01.xml#L124
None of the codings provided are in the value set 'LandCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.10--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = urn:iso:std:iso:3166#NL)
Loose QA on the entire repo: examples/nl-core-MedicalDevice-03.xml#L39
None of the codings provided are in the value set 'LocatieCodelijsten' (http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.121.11.11--20200901000000|2020-09-01T00:00:00), and a coding from this value set is required) (codes = http://snomed.info/sct#9454009)
Loose QA on the entire repo: resources/zib/zib-Refraction.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.20.7.2--20200901000000 could not be expanded
Loose QA on the entire repo: resources/zib/zib-HelpFromOthers.xml#L1
The slice definition for CarePlan.activity.detail.performer has a maximum of 1 but the slices add up to a maximum of 3. Check that this is what is intended
Loose QA on the entire repo: resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
Loose QA on the entire repo: resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
Loose QA on the entire repo: resources/zib/zib-VisualFunction.VisualAid.Product.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.1.1--20200901000000 could not be expanded
Loose QA on the entire repo: resources/zib/zib-HearingFunction.HearingAid.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
Loose QA on the entire repo: resources/zib/zib-HearingFunction.HearingAid.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
Loose QA on the entire repo: resources/zib/zib-HearingFunction.HearingAid.Product.xml#L1
Binding http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.1.1--20200901000000 could not be expanded
Loose QA on the entire repo: resources/zib/zib-MedicalDevice.Product.xml#L1
The slice definition for Device.identifier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended
Loose QA on the entire repo: resources/zib/zib-MedicalDevice.Product.xml#L1
The slice definition for Device.udiCarrier has a maximum of 1 but the slices add up to a maximum of 2. Check that this is what is intended