Switchtec-user v3.1 Release
About this Release
This release supports the following Switchtec devices and releases:
Generation | Variant | Release |
---|---|---|
Gen5 | PFX/PSX | FCA (F/W version: 06.01.0.01f) |
Gen4 | PFX/PSX | MR-1 (F/W version: 03.60.0.049), MR-2 (F/W version: 03.70.0.04f), MR-3 (F/W version: 03.80.0.056), MR-4 (F/W version: 03.90.0.05b) |
Gen4 | PAX | MR-1 (F/W version: 04.60.0.449), MR-2 (F/W version: 04.70.0.450), MR-3 (F/W version: 04.80.0.456), MR-4 (F/W version: 04.90.0.45b) |
What is New Since v3.0 Release?
This release introduces the following new features, changes and fixes
Features and Changes
-
diag
submenu: added the following new diagnostic commands
eye
: display eye diagram of a port
crosshair
: measure eye cross hair of a port
list-mrpc
: list permissible MRPC commands
loopback
: enable loop back test on specified ports
pattern
: enable pattern generation and monitor
port-eq-txcoeff
: dump port equalization coefficients
port-eq-txfslf
: dump FS/LF output data
port-eq-txtable
: dump far end port equalization table
rcvr-extended
: dump RX mode and DTCLK
rcvr-obj
: dump analog RX coefficients/adaptation objects
refclk
: enable or disable the output reference clock of a stack
ltssm-log
: display LTSSM log -
log-dump
: addedEvent ID
field in text log files -
fw-read
: changed default output file name toimage.fwimg
for Gen4 and later devices
Fixes
status
: fixed segmentation fault found on ARM platform onlylog-parse
: fixed missing Firmware/SDK version number when parsing mailbox log files
Limitations
-
GAS dump
Switchtec-user commandgas dump
might impact system performance or cause instability -
FABRIC commands
fabric
submenu commands are not yet supported on Gen5 device -
DIAGNOSTIC commands
diag
submenu command are for Gen4 device only