Version 3.3.2, 8 July 2024

  • Improve chip testing mode, and give a more direct warning against using chip test mode for headstages
  • Flush livenotes file every time a livenote occurs (useful for real-time applications that rely on livenotes)
  • Fix XML loading of Port-specific parameters (manual delay, auxiliary digital out assignment) failing after Port A
  • Fix intermittent crashing that would occur from hovering cursor in tooltip mode over border between signal types in plot

Version 3.3.1, 5 December 2023

  • Add 10, 16, and 20 ms time scale options for Spike Scope
  • Fix intermittent Stim Parameters dialog initialization issue that could cause incorrect values to appear
  • Append date/timestamp to end of LiveNotes filename to avoid unintentional file overwriting for multi-file recording sessions
  • Improve TCP functionality to allow for multiple connections/disconnections to occur without having to restart software
  • Add TCP "execute" commands: SaveSettingsFile, LoadSettingsFile, SaveStimulationSettingsFile, LoadStimulationSettingsFile, analogous to already present UI elements.
  • Improve test mode: wider acceptable input signal ranges, reduced likelihood of unintentionally entering test mode, and faster chip testing

Version 3.3.0, 23 August 2023

  • Improve TCP reception of commands to not duplicate slot connections.
  • Add Chip Test Mode.
  • Fix issue where for RHD chips, Rescan Ports would not run chip calibration
  • Fix 7310 bit files so that for RHS systems, using a sample rate other than default (30 kHz) will no longer cause the software to use the wrong sample rate.
  • Fix crashing when attempting to open a new file for recording fails, instead display an error message and stop acquisition.

Version 3.2.0, 3 March 2022

  • Allow user to specify which port(s) to read data from in Advanced dialog
  • For One File Per Channel file format, when playing back data as it's being written, allow for jumping to the end of data for near-real-time playback
  • Support for use of XEM7310 board in Intan controllers to replace XEM6010 and XEM6310
  • Allow user to specify use of median instead of average for reference calculations
  • Fix various issues with re-recorded playback data dropping data blocks at the end
  • Allow user to specify whether or not to use max # of channels possible in synth mode
  • Add "Get CurrentTimestamp" and "Get CurrentTimeSeconds" TCP commands
  • Improved error detection and reporting for TCP commands
  • Various improvements in RHX API including easier use of the API without Qt, and additional utility functions described in Rhythm and RhythmStim documentation.

Version 3.1.0, 6 June 2022

  • Fixed memory issue that caused systems with multiple RHD2216 chips to erroneously duplicate channels.
  • Added Plotting Mode options in the Performance menu, including a new High Efficiency mode that plots data more efficiently.
  • Allowed some elements (including window size, position, and control panel state) of the basic GUI appearance to automatically load/save through QSettings.
  • Added current channel name to the Window Title of the Spike Scope, ISI, PSTH, and Spectrogram tools.
  • Added current loaded filename to the Window Title of the Probe Map tool.

Version 3.0.6, 1 April 2022

  • Fixed bug with FilePerChannel digital ins/outs not being indexed correctly.
  • Increase max number of columns to 16.
  • Put waveform display in a scroll area so that when too many columns are present to be displayed at once, a scroll bar can be used.

Version 3.0.5, 3 February 2022

  • Removed unused Context Help buttons from dialogs.
  • Reduced latency of spike .dat file writing so that these files are updated as soon as spikes are detected.
  • Added option to start software without OpenCL.
  • Improved TCP parsing to handle unexpected whitespace in a string of commands.
  • Added WriteToDiskLatency setting for users to control.
  • Added CreateNewDirectory setting for users to control.
  • Fixed displaying 'save to disk' icon for enabled non-amplifier signals (e.g., aux in, digital in, analog in).
  • Fixed small memory leak during TCP data streaming.
  • Altered 'Rescan Ports' behavior so that if the system went from no headstages to at least one detected, the displayed port will update to the present chip(s).
  • Added drag'n'drop option for various settings files.
  • Added more descriptive error messages when a Probe Map file is loaded as a general settings file.

Version 3.0.4, 5 August 2021

  • Fixed small memory leak that occurred when saving in the File Per Signal Type file format.
  • Improved XML settings file parsing so that files that don't include any headstage channels can still be correctly loaded.
  • Minor improvement to make error logging more detailed and efficient.
  • Modify episodic triggered recording algorithm to ignore brief trigger-off events.
  • Improved optimum SPI delay finding algorithm so that setting delay manually is less likely to be necessary.
  • In data file playback mode, electrode impedances are now displayed.
  • Fixed issue with external fast settling in RHD systems not properly triggering as a result of digital input activity

Version 3.0.3, 15 April 2021

  • Added 50 ms option to PSTH pre-trigger and post-trigger spans.
  • In "One File Per Signal Type" data file format, added option to save auxiliary inputs (e.g., acccelerometer data) in amplifier.dat file.
  • Fixed bug that sometimes causes crashing when PC audio was enabled.
  • Fixed bug that did not display auxiliary inputs or supply voltages from second headstage when dual headstage adapter was used.
  • Expanded OpenCL compatibility to fix problems with OpenCL initialization on some systems.

Version 3.0.2, 24 March 2021

  • Improvements to Spike Scope:
    • Added RMS display, consistent with old software.
    • Added spike rate display.
    • Number of spikes in recent spike history can now be as high as 500.
    • Each channel's recent spike history is persistent when channels are changed.
    • Added 'Take Snapshot' and 'Clear Snapshot' buttons to permit freezing spike history in background of display on a per-channel basis.
  • Added longer post-trigger spans to PSTH tool: 5s, 10s, and 20s.
  • Added ability to use analog inputs as digital triggers in PSTH tool.
  • Added ability to use analog inputs as digital triggers in Display Trigger (in Trigger tab).
  • Added ability to display thresholded analog inputs as digital signals in Spectrogram Tool.
  • In data file playback mode, added 'run immediately' option after 'jump to position'.
  • Extended range of y-axis spacing between waveforms on waveform display.
  • Fixed bug where 'Stop' button was not working during rewinding.
  • Fixed bug where the 'Automatically Save Trigger Channel' option in triggered recording was not working.
  • Fixed issue where software crashed upon exiting on some Macs.
  • Fixed crashing upon software startup with some smaller screens.
  • Improvements to TCP output:
    • Added ability to disable and enable individual channels for TCP output while system is running.
    • Improved TCP parser so that path names and file names may include spaces.
    • Fixed TCP output timestamps to match timestamps in recorded data.
    • Fixed issue where TCP data output could fill up software 'Waveform FIFO' buffer under certain conditions.
    • Changed TCP parameter name 'DisplayTriggerAnalogVoltageThresholdVolts' to 'TriggerAnalogVoltageThresholdVolts'.
  • Switched to latest version (v5.2.3) of Opal Kelly DLL.
  • Changes to support Linux compilation.
  • Windows installer:
    • Fixed issue where certain anti-virus programs would interfere with Windows installation.
    • Added additonal DLLs to Windows installation:
      api-ms-win-core-winrt-string-l1-1-0.dll
      api-ms-win-core-winrt-l1-1-0.dll
      OpenCL.dll

Version 3.0.1, 12 February 2021

  • Fixed bug that caused crash during electrode impedance measurement.

Version 3.0, 11 February 2021

  • First release; started with v3.0 to avoid confusion with older Intan software.