[Device Support Request] Circuit Breaker 63A with Power Monitoring and Threshold TS011F | _TZ3000_lepzuhto #2652
Comments
Tongou TO-Q-SY2-163JZT - TS011F _TZ3000_cayepv1a. Wrong amperes (always show 62-63), wrong measurements (kWh), no threshold. |
Same problem with Tongou TO-Q-SY2-163JZT - TS011F _TZ3000_cayepv1a { Ampere is x 1000 Cumulated power is x 100 Edit on 29 march 24 |
TS011F by _TZ3000_cayepv1a
|
If we are talking abut the same device (TO-Q-SY2-163JZT) , and I think we are, the integration into ZHA needs a lot of work. As it is right now this device function as TO-Q-SY1 device, which is just a normal breaker with an ON/OFF button and displaying some power values.
This is the zigbee2mqtt page for this device: https://www.zigbee2mqtt.io/devices/TO-Q-SY2-163JZT.html Will be good to see the same kind of functionality in ZHA too because with out that it will just acts like a dumb TO-Q-SY1 device offering no protection at all. The pic below shows what this device exposes in zigbee2mqtt: |
Hello, I just received this device.
@dartvader1234 : you correctly detected the problem (1). You should have a look at the following discussion. Someone had the same problem with another device and solved (1) with a custom quirck (but not (2)). The problem (2) was identified in the thread above but not solved. If you check P=UI you will see that the power value is incorrect. Are everyone here using 220v? Anyone using 11v? The guess from the other thread is that TUYA calculate power from 110v. I hope someone will be able to write a custom quirck inspired from this one: |
9After some more testing, here are more info. 2/ about the values measured by _TZ3000_cayepv1a:
Value measured with an external tool (simple AC clamp meter) = 0.130A Let's simplify for now and says that there is a x1000 factor. There will still be a huge difference between 130 and 194. Can it be explained by the relatively low current and the method (AC clamp)?? Later I'll connect an amperemeter to get a more precise value.
Unfortunately I'm not able to write a custom quirk. I hope those info will help someone write one on the basis of this one: custom quirk for tuya clamp For all others: you can make a simple correction using templates |
@dartvader1234: can you please double check your power value? are your sure you do not read a value/2 ?? |
You are rigth, me wrong, cumulated power is x 100 |
Hi, Taken from here: |
Thank you mortiy. 👍 |
I have TO-Q-SY2-JZT - TS011F _TZ3000_cayepv1a with There is a quirk for similar device _TZ3000_qeuvnohg having the same descriptor, but with slightly reordered clusters:
I suppose tweaking this quirk should help to identify the _TZ3000_cayepv1a device properly? |
Hi, please excuse the simple question, I too have this device (TO-Q-SY2-163JZT) and am using ZHA, and have noticed the lack of exposed sensors compared to Zigbee2mqtt (within this thread), will this be updated/rectified overtime, are there manual interventions/configuration changes needed to identify the current product? I am primarily using the switching function (noted the wrong current values) the other sensors are nice to have. Thanks in advance… |
Another vote for fixing this please. |
I can send one TS011F by _TZ3000_cayepv1a to the developper team, for free to resolve this problem. If your are interested, please contact me. I will reply you by email |
I create a custom quirk for this device here |
I updated the file to make use of the quirk v2 features to expose the attributes to HA entities |
Updated version with quirks v2 support |
Problem description
Electrical measurements in this device not working properly - current and summation delivered (kWh) are too high.
Solution description
Please correct the current multiplier