1. Introduction

RMA stands for Return Material Authorization. If a hardware failure is determined by the JTAC engineer and repair/replacement is needed, an RMA will be created. This RMA provides the customer with the ability to return the specified defective unit for replacement in line with the purchased SLA (Service Level Agreement).

2. Problem statement

As of today there is no support for RMA via Contrail Command. There is a need for putting the RMA workflow in place to support the repair/replacement of Juniper devices. The user should be able to just enter the serial number of the new device and be able to replace it in place of the old device seamlessly.

Usecase 1:

Customer should be able to RMA a device that has been on-boarded using the brownfield workflow. In this scenario the underlay configuration is not managed by Contrail.

Usecase 2:

Customer should be able to RMA a device that has been on-boarded using the greenfield workflow. In this scenario both the underlay and the overlay configuration is managed by Contrail.

3. Proposed solution

The RMA support in Contrail will include the following changes/additions:

  1. To provide support for RMA, the device underlay configuration is backed up before any configuration is pushed onto it from Contrail during device on-boarding step. This is required only in the brownfield workflow.
  2. The user will be able to put the device into 'RMA' state by selecting the 'RMA device' action in the Fabric Devices page.
  3. Once the replacement device is in place and wired into the network, the user can select the action 'RMA activate'. The user will then be prompted to enter in the serial number of the new device if he has not entered it yet. The user can enter the serial number either by editing the device directly or after selecting the device to be reactivated. Once this is done, Contrail will internally push the backed up configurations (in case of brownfield usecase) and also automatically apply the same roles as the earlier device.
  4. For greenfield workflow, the new plugged in device will also be upgraded to the the os version if specified by the user during fabric creation.

Notes:

  1. When the device is being replaced with the new one the management IP address, underlay configuration, ASN number, loopback addresses must not be changed. The old values should be retained.
  2. The new device should be of the same model and os version as the old one.
  3. The new device should be wired exactly the same as the old one into the network.
  4. The out of band configuration changes (the configuration changes done manually) on the device after the configuration has been backed up during the onboarding step will not be backed up. Backup/restore of out of band changes is not supported.

4. User workflow impact

The following screenshots capture the use visible changes

- Add "RMA device" to Fabric devices -> Action

RMA Device

- Pop up warning dialog for above action

RMA Device Pop-up

- Add "RMA activate" state to Fabric Device edit screen

RMA Activate Edit

- Add "RMA activate" to Fabric devices -> Action

RMA Activate

- Pop up RMA activate dialog box with serial number input

RMA Activate Pop-up

5. Alternatives considered

(None)

6. API schema changes

RMA Activation Workflow

There will be a new job template called "rma_activate_template" with the following json input schema:

  "input_schema": {
    "title": "RMA activate",
    "$schema": "http://json-schema.org/draft-06/schema#",
    "type": "object",
    "additionalProperties": false,
    "properties": {
      "fabric_uuid": {
        "type": "string",
        "description": "Fabric UUID"
      },
      "rma_devices": {
        "type": "array",
        "items": {
          "title": "RMA Devices",
          "type": "object",
          "description": "List of devices and corresponding serial numbers to RMA",
          "additionalProperties": false,
          "properties": {
            "device_uuid": {
              "type": "string",
                "format": "uuid"
            },
            "serial_number": {
              "type": "string"
            }
          },
          "required": [ "device_uuid", "serial_number" ]
        }
      }
    }
  }

The input for the execute-job for device RMA activate will look like this:

6.1 Greenfield

{
  "job_template_fq_name": ["default-global-system-config", "rma_activate_template"],
  "input": {
    "fabric_uuid": <fabric_uuid>,
    "rma_devices": [
      {
        "device_uuid": <device_uuid_str_1>,
        "serial_number": <serial_number_str_1>
      },
      ...
    ]
  }
}

6.2 Brownfield

NOTE: It is expected that brownfield devices will require a seperate job template. Since brownfield support has been delayed, the precise API is still TBD.

{
  "job_template_fq_name": ["default-global-system-config", "rma_existing_activate_template"],
  "input": {
    "fabric_uuid": <fabric_uuid>,
    "rma_devices": [
      {
        "device_uuid": <device_uuid_str_1>,
        "serial_number": <serial_number_str_1>
      },
      ...
    ]
  }
}

Physical Router Changes

The physical_router object will have the following schema additions:

  • New physical_router.physical_router_managed_state field with these values: "rma", "activating", "active"
  • New physical_router.physical_router_underlay_config field to store underlay config of brownfield device

7. UI changes

See section 4 "User Flow Impact".

8. Notification impact

(None)

9. Provisioning changes

(None)

10. Implementation

10.1 Data model changes

  • New physical_router.physical_router_managed_state field with these values: "rma", "activating", "active"
  • New optional fabric_os_version field that includes string value of os-version specified during green field workflow.

10.2 Save brownfield configuration during device import

  • Brownfield only: During device import, underlay configuration is always read from the device and stored on the physical_router.physical_router_underlay_config field in the VNC database,
  • Need to ensure this underlay_config is not too big.

10.3 Put device into RMA state

  1. UI changes managed_state of physical_router object to "rma"
  2. Device Manager senses this state change and sets an internal do-not-push flag indicating that the configuration for this device should not be pushed

10.4 Configure new device serial number

  1. If desired, enter the serial number of the new device on the device information page in the UI. If the serial number is not set here, it can optionally be set in the next step.

10.5 Put device into active state

  1. UI calls rma_activate device workflow via execute-job API with device UUID and optional serial_number input
  2. Device Manager starts rma_activate device job and rma_activate Ansible playbook invoked:
    • Read physical_router object from database
    • Update serial_number if provided with input
    • Change physical_router managed state to "activating"
    • If brownfield device, fetch underlay_config and push to device
    • If greenfield device, invoke IP assignment task, upgrade device to fabric_os_version if specified.
    • Change physical_router managed_state to "active"
  3. Device Manager senses this state change, clears the do-not-push flag, and pushes the overlay config to the device

10.5.1 Workflow error handling

  • If missing serial_number, fail
  • If missing underlay_config for brownfield device, fail
  • If reactivation fails, ensure that the device is in RMA state itself

11. Performance and scaling impact

The RMA workflow itself is only expected to be executed one at a time, so there is minimal scaling impact anticipated.

Saving brownfield configuration could be impactful if this configuration is large. Performance could be impacted when saving the configuration during device import. Performance could also be impacted during reactivation if the device.

12. Upgrade

(None)

13. Deprecations

(None)

14. Dependencies

(None)

15. Testing

https://drive.google.com/file/d/12hBG76OrqM8Iha7OoSVj4cBMJ1QZhQS8/view

16. Documentation Impact

Requires new section on RMA

17. References

18. Issues

  • What to do if underlay_config is too big?