Skip to content

Latest commit

 

History

History
492 lines (414 loc) · 49.1 KB

CHANGELOG.md

File metadata and controls

492 lines (414 loc) · 49.1 KB

OpenStudio v1.11.2

2016-05-02 — Diff
  • Fixed: #1627, HVAC Tab - Low Temp Radient components come in without any names
  • Fixed: #2203, Ruby inside of Mac installer won't load openstudio bindings
  • Fixed: #2207, Fix exterior lights on standard report
  • Fixed: #2208, Fix Variable Speed Pump reporting in standard report

OpenStudio v1.11.1

2016-04-21 — Diff
  • Fixed: #1359, EnergyPlus does not update standard output during run
  • Fixed: #2181, Add "high" accuracy settings option to Radiance Measure
  • Fixed: #2186, SketchUp does not see plugin signature as valid
  • Fixed: #2191, MultiSpeed Coil Inlet/Outlet Nodes Not Being Connected Properly

OpenStudio v1.11.0

2016-03-28 — Diff
  • Fixed: #2169, Adding comments only
  • Fixed: #2171, Unit test fixes

OpenStudio v1.10.6

2016-03-22 — Diff
  • Fixed: #1916, Open Studio does not provide an error message when running VRF systems without cooling or heating schedules.
  • Fixed: #2005, Run Simulation Tab Says "Hello World" When Using Apply Measure Now
  • Fixed: #2007, alphabetize HVAC Systems list
  • Fixed: #2034, App closes when Air Loop availability schedule is set to blank and the 'Control' button clicked.
  • Fixed: #2037, HeatExchanger:FluidToFluid problems
  • Fixed: #2043, CoilHeatingWaterToAirHeatPump:EquationFit forward translator sets hard sized rated water flow rate as air flow rate
  • Fixed: #2046, HVAC templates should have a water cooled chiller and an air cooled chiller.
  • Fixed: #2055, PAT datapoints with comma's in name fail to run
  • Fixed: #2080, Deleting AirTerminal with reheat does not delete HW coil
  • Fixed: #2081, Dropping Schedule
  • Fixed: #2086, Mismatch between OpenStudio and EnergyPlus idd choice for PlantLoop Load Distribution Scheme
  • Fixed: #2097, Update OS to E+ 8.5
  • Fixed: #2098, air loop diagram
  • Fixed: #2149, Fix Date/Time Of Peak query in EnergyPlus 8.5
  • Fixed: #2153, Fails to import IDF when CondenserLoop is part of IDF
  • Fixed: #2155, 1.10.5 closes after apply measure now

OpenStudio v1.10.5

2016-03-08 — Diff
  • Improved: #1123, Better Radiance Preflight Testing
  • Fixed: #643, Radiance Forward Translator Bugs
  • Fixed: #775, Crash on delete air loop (on second loop I delete)
  • Fixed: #1349, Measure Groups Rename on Reorder
  • Fixed: #1473, Add Import / Load Library Feature for MEP Schedules
  • Fixed: #1589, Launch OS button doesn't work for OSM files on network drives
  • Fixed: #1684, Crash when editing string argument value after running a successful simulation.
  • Fixed: #1730, ModelObjects not translated to E+
  • Fixed: #1870, PAT 1.8.0 - An unhandled exception has occurred - AnalysisDriver.cpp - Invalid Results
  • Fixed: #1901, Fix Radiance translator's reporting behavior
  • Fixed: #1915, OpenStudio App loses weather file
  • Fixed: #1969, Using "x2" in app on thermal zone removes thermostat from other zones that used it.
  • Fixed: #1999, Model does not display in SketchUp
  • Fixed: #2001, Copying a measure produces invalid measure if "ended" is in description string (probably also issue in name and modeler description)
  • Fixed: #2024, .osm files disappear from computer, possibly caused by uninstalling and reinstalling OpenStudio and Sketchup applications
  • Fixed: #2030, PAT 1.10.0 run time depends on number of External File User Defined Measures
  • Fixed: #2045, draw dual ducts
  • Fixed: #2051, Mac packages fail at runtime due to geo lib
  • Fixed: #2060, PAT 1.10.0 Run tab breaks if run cancelled
  • Fixed: #2061, PAT 1.10.0 stops working if user changes User Defined Measure category
  • Fixed: #2070, SetpointManager:Coldest translates to two identical energyplus objects
  • Fixed: #2078, Fix ShadingControl solar setpoint and units handling
  • Fixed: #2088, PAT XML export is not exporting user-defined names
  • Fixed: #2089, Radiance measure blows up real good on large models
  • Fixed: #2090, OS 1.10.0 Win 64 App does preserve inherited relationships for constructions assigned to surfaces and sub surfaces
  • Fixed: #2092, PAT deletes all datapoints after closing and reopening
  • Fixed: #2094, PAT Cloud not working in 1.10.0
  • Fixed: #2101, Unit problem for “Add Daylight Sensor at the Center of Space” measure
  • Fixed: #2113, Air wall construction missing

OpenStudio v1.10.4

2016-02-21 — Diff
  • Fixed: #1929, Radiance Measure flails when initial E+ run fails.
  • Fixed: #1930, Support switchable glazing in Radiance Measure
  • Fixed: #2064, CBECC generated files fail to open in current OS (1.10.2)
  • Fixed: #2065, Tariff Selection Time And Date Dependent measure has wrong season for winter demand charge
  • Fixed: #2069, Fix delta temperature in design day table
  • Fixed: #2071, Missing Object Types in Sketchup Plugin Inspector
  • Fixed: #2072, Cannot create thermostats in Sketchup 2016 with OS 1.10
  • Fixed: #2074, Deleting space orphans lifecycle cost objects that had been associated with the space
  • Fixed: #2082, Autosize water heater ends in IDF without WaterHeater:Sizing object
  • Fixed: #2083, Fix Radiance version sniff

OpenStudio v1.10.3

2016-01-21 — Diff
  • Improved: #713, Support multiple glare sensors per space
  • Improved: #985, Allow shared thermostats
  • Improved: #1968, Add new oa method to ControllerMechanicalVentilation
  • Fixed: #123, Address changes made to shared thermostats with make unique (Bugzilla #722)
  • Fixed: #1897, Biquadratic curve min/max value edits not retained
  • Fixed: #2012, Fix Glare Sensor Support
  • Fixed: #2026, PAT is breaking 1.9.0 files when opening with 1.10
  • Fixed: #2040, New Geo lib breaks OpenStudio-Resources build
  • Fixed: #2042, Assign thermostat to zones problem
  • Fixed: #2049, fix ownership issues with zone controllers
  • Fixed: #2056, Radiance Path Order

OpenStudio v1.10.2

2016-01-21 — Diff
  • Fixed: #1713, open studio not working on windows 8.1
  • Fixed: #1947, Expose all fields of the Sizing:Zone object
  • Fixed: #2028, Forward Translation error when multiple spaces of same space type in a zone when load type is design load

OpenStudio v1.10.1

2016-01-08 — Diff
  • Fixed: #1959, Building of OpenStudio on Mac doesn't find EnergyPlus or Radiance
  • Fixed: #2002, Removing arguments from a measure leaves orphan arguments in XML
  • Fixed: #2003, GUI Configuration Failure - OS 1.9.0 and 1.9.5 for Load Profile Plant Object
  • Fixed: #2004, 64 bit C# bindings have a 32 bit dll
  • Fixed: #2014, OpenStudio application 1.10

OpenStudio v1.10.0

2015-12-11 — Diff
  • Fixed: #1526, Floor/Ceiling Constructions creating issues with construction.getNetArea method
  • Fixed: #1608, Thermal Zone tab crash when editing zone equipment
  • Fixed: #1831, Select All in GridView should only select all rows/sub-rows that are currently visible (i.e. unfiltered)
  • Fixed: #1881, Default constructor for PlantEquipmentOperation:OutdoorDryBulb has temp limits reversed
  • Fixed: #1951, PAT 1.9.4 crashes when creating a new project or opening an existing one
  • Fixed: #1963, Render by surface type leaves some surfaces transparent
  • Fixed: #1971, OS:LoadProfile:Plant Object not functioning properly
  • Fixed: #1977, Setpoint managers are not allowed on plant demand side
  • Fixed: #1983, AddOutputVariable measure should support the "annual" reporting frequency
  • Fixed: #1984, View_data Measure Doesn't Rotate Shading Surfaces when North Axis is Rotated
  • Fixed: #1985, Control For Outdoor Air Field Not Initialized In AirTerminal Causes Crash
  • Fixed: #1986, Link to measure writing guide in new measure is wrong
  • Fixed: #1995, Induction terminals (still) not disconnecting cleanly

OpenStudio v1.9.5

2015-11-25 — Diff
  • Improved: #1394, OS -> SDD Translate ZoneHVAC
  • Fixed: #1905, Crash when clicking on Solar Flat Plat Collector in Plant Loop
  • Fixed: #1919, ZoneVentilation:DesignFlowRate won't work on zones without any zone equipment.
  • Fixed: #1924, SketchUp Plugin doors default to "glass door" vs. door
  • Fixed: #1936, Controller:WaterCoil node references not cleaned up on airloop edit
  • Fixed: #1948, OS 1.9 loses space loads when converting v1.8 model
  • Fixed: #1949, PAT and ResultsViewer 1.9.3 won't launch
  • Fixed: #1954, Crash before run simulation
  • Fixed: #1956, OS App 1.9.4 crashes in Apply Now when changing selected measure

OpenStudio v1.9.4

2015-11-12 — Diff
  • Improved: #1911, Add support for E+ 8.4
  • Improved: #1921, Add water to water heat pump
  • Fixed: #1460, Inherited Default Construction and Schedule Sets Not Displayed in Facility Tab
  • Fixed: #1598, dynamic generated argument choice values in measure.xml
  • Fixed: #1812, Build Win Version Ruby - Product extension is set to .so
  • Fixed: #1847, Space Tab - Shading sub tab is missing Shading Surface Name column
  • Fixed: #1861, Default BoilerHotWater::BoilerFlowMode
  • Fixed: #1892, Application says "Drop Zone" instead of "Drop Space Type" in the space type tab
  • Fixed: #1893, 1.9.0 Space tab: do not see inherited properties
  • Fixed: #1896, constructionId for SubSurface translated to Surface
  • Fixed: #1899, Crash when viewing plant loop on user model
  • Fixed: #1928, Unable to assign thermalZone to Inverter
  • Fixed: #1932, PAT XML Export is missing cash flow results in 1.9

OpenStudio v1.9.3

2015-11-02 — Diff
  • Improved: #1907, Enable Design OA spec on terminal
  • Fixed: #1734, Weather file location 1.8.1
  • Fixed: #1900, User has to specify at least one measure on alternate model in PAT
  • Fixed: #1902, LayeredConstruction::visibleTransmittance doesn't work on multiple layer constructions
  • Fixed: #1917, Bug Report - Thermostat
  • Fixed: #1923, ElectricalLoadCenter:Generators is missing

OpenStudio v1.9.2

2015-10-19 — Diff
  • Improved: #1303, Can't make choice arguments from model for E+ measures
  • Fixed: #298, weather (epw) and ddy file path issues (Bugzilla #1163)
  • Fixed: #1549, Coordinate fine/coarse Sky Subdivision Params in idd
  • Fixed: #1555, Cannot set or view site name in app
  • removed: #1907, Removed method AirTerminalSingleDuctVAVNoReheat::designSpecificationOutdoorAir in favor of a more user friendly API.

OpenStudio v1.9.1

2015-10-01 — Diff
  • Fixed: #1886, Incorrect units for Refrigeration Walk-In Construction U-value
  • Fixed: #1894, 1.9.0 Turning off "Run for sizing period" yet it still seems to run them

OpenStudio v1.9.0

2015-09-25 — Diff
  • Fixed: #404, OS App Water Use Equipment Definitions, Peak Flow Rate Units always in SI units
  • Fixed: #470, Odd temps on outdoor air temp reset in OS app
  • Fixed: #593, Node.addSetPointManager() does not accept all types of Setpoint Managers
  • Fixed: #1005, Coil Cooling/Heating Water to Air HP wrappers are empty in UI
  • Fixed: #1135, Radiance Parameters are reset to Coarse every time the osm is loaded
  • Fixed: #1347, Update web-assets for 1.6.0 package
  • Fixed: #1365, Design Flow Air Rate in CoilCoolingWater object uses fluid vs. air units
  • Fixed: #1468, Change peak flow rate in water use equipment definitions from cfm to gal/min
  • Fixed: #1543, Seeing "Autocalculate" in Maximum Air Flow Rate for terminal object
  • Fixed: #1547, SpaceType Tab - Load filter should function on infiltration objects
  • Fixed: #1604, PumpConstantSpeed - PumpFlowRateSchedule not in schedule registry
  • Fixed: #1610, boiler efficiency curve causes fatal error
  • Fixed: #1636, Output Control Reporting Tolerance units default to SI despite app unit preference
  • Fixed: #1657, SketchUp Plug-in installation error message does not apply to all cases
  • Fixed: #1703, Radiance simulation does not use the EnergyPlus installed with OpenStudio
  • Fixed: #1749, Missing SetpointManager:Scheduled icon
  • Fixed: #1757, Schedule Sets sub tab "My Model" doesn't populate at first
  • Fixed: #1771, AirTerminalSingleDuctSeriesPIUReheat leaves ZoneHVAC:EquipmentList in bad state
  • Fixed: #1784, Crash When Deleting HPWH
  • Fixed: #1804, Pipe:Adiabatic icon doesn't show, OS 1.8.4 Develop Branch on Windows
  • Fixed: #1819, Material in templates is missing roughness and causes failed simulation
  • Fixed: #1834, Changing minimum values in SpaceInfiltration:DesignFlowRate object
  • Fixed: #1836, Fresh develop build Crash "Bad cast" after clicking on "Spaces" tab
  • Fixed: #1839, component setpoint operation scheme logic is flawed
  • Fixed: #1840, AVM Night Cycle Issue
  • Fixed: #1843, Space Tab - Subsurfaces sub-tab in lets you make new spaces with green "+"
  • Fixed: #1844, Space Tab - Shading Controls sub-tab
  • Fixed: #1845, Default low temp radiant variable flow setpoint schedules reversed
  • Fixed: #1853, Number of WaterHeater:Stratified Nodes Fixed at One
  • Fixed: #1859, IP unit errors
  • Fixed: #1863, LoadProfilePlant default load schedule is incorrect
  • Fixed: #1866, PlantLoop::remove doesn't work!
  • Fixed: #1868, PAT 1.8.5 hanging when running multiple simulations
  • Fixed: #1873, Building Stories not exposed in "My Model" pane for Spaces > Property sub-tab
  • Fixed: #1874, WaterHeater:Mixed is missing form My Model, prevents some user use cases
  • Fixed: #1875, When you make a new schedule "Temperature" shows up twice in the Schedule Type list.
  • Fixed: #1879, OS App creates simulation settings objects different from E+ defaults
  • Fixed: #1887, Deleting a plant component can orphan a node
  • Fixed: #1891, Application is freezing when trying to remove plantloop from model 0

OpenStudio v1.8.5

2015-09-04 — Diff
  • Added: #1670, Add support for heat pump water heater
  • Added: #1679, Add Support of dual duct systems and related components.
  • Added: #1712, Add missing availability managers
  • Added: #1774, Add miscellaneous remaining objects
  • Improved: #1441, Ship Radiance with OpenStudio
  • Fixed: #937, Create From External File + facility.exteriorLights crashes ruby
  • Fixed: #1496, Installer puts 64 bit E+ in 32 bit OS installer.
  • Fixed: #1577, Scan for tools finding wrong EnergyPlus version
  • Fixed: #1601, PAT ruby script path not set
  • Fixed: #1617, Repeatable crash when loading specific seed model
  • Fixed: #1656, VRF OA Unit IG policy
  • Fixed: #1695, The min. cfm/sf value in the zone:sizing object is being converted from IP to SI wrong in OS 1.7.0
  • Fixed: #1701, Deleting plant equipment with setpoint schedule on outlet node orphans setpoint schedule
  • Fixed: #1706, Zones with FanZoneExhaust require thermostat schedules
  • Fixed: #1730, ModelObjects not translated to E+
  • Fixed: #1740, Detached drop downs
  • Fixed: #1746, OpenStudio 1.8.0 does not work with installed E+
  • Fixed: #1747, SetpointManager:Scheduled crash
  • Fixed: #1755, OpenStudio App crash on user file
  • Fixed: #1762, Documentation for removeSupplyBranchWithComponent is incorrect
  • Fixed: #1763, An unhandled exception has occurred. Access violation - no RTTI data
  • Fixed: #1778, Incorrect SI to IP unit conversion in sizing:zone gridview
  • Fixed: #1779, Can't Delete the First OS:WaterHeater:Stratified object Added to Plant Loop Using Measure
  • Fixed: #1780, WaterHeating:AirToWaterHeatPump Rated Condenser Inlet Water Temperature Forcing Random Value
  • Fixed: #1786, Issue with Python bindings for v1.8.0
  • Fixed: #1787, Orphaned connections when deleting Air-to-Air HX from outdoor air system with other outdoor air equipment
  • Fixed: #1795, Hide "Apply to Selected" for Outside Boundary Condition Object
  • Fixed: #1808, Effective Air Leakage Area Units Incorrect
  • Fixed: #1810, OS version test failing
  • Fixed: #1815, Install Radiance with OpenStudio
  • Fixed: #1816, EDAPT XML not encoded in UTF-8
  • Fixed: #1817, Need to warn user if IP units measure is used
  • Fixed: #1834, Changing minimum values in SpaceInfiltration:DesignFlowRate object

OpenStudio v1.8.4

2015-08-24 — Diff
  • Added: #1744, Added new setpoint managers
  • Added: #1759, Added new coils
  • Added: #1773, Added new ZoneHVAC objects
  • Added: #1707, Added Dual Duct
  • Added: #1719, Added Duct, FluidCoolerSingleSpeed, FluidCoolerTwoSpeed, PipeIndoor, PipeOutdoor
  • Added: #1727, Added new availability managers
  • Added: #1739, Added ZoneMixing
  • Added: #1742, Added solar collectors
  • Added: #1769, Added Plant operation schemes
  • Added: #1788, Added misc objects
  • Added: #1782, Added Zone ventilation design flow rate
  • Improved: #1764, Radiance functionality refactored as a measure
  • Improved: #1642, Add Space Infiltration Effective Leakage Area object to library files
  • Fixed: #1758, OpenStudio::EpwFile.new() crashes on Linux
  • Fixed: #1767, Hard Crash Opening 1.5.3 CBECC-Com OSM in 1.8.3
  • Fixed: #1770, Facility tab grid view crash
  • Fixed: #1776, WaterHeaterStratified does not work with HPWH
  • Fixed: #1781, OpenStudio measure without measure.rb file crashes PAT
  • Fixed: #1783, Files won't open with OS App 1.8.3
  • Fixed: #1766, Update DiagnosticScript to remove cruft from badly initialized zones

OpenStudio v1.8.3

2015-08-10 — Diff
  • Added: #1388, Allow users to specify costs and ECMs on external models imported to PAT
  • Added: #1711, Facility tab grid view
  • Improved: #854, Radiance FwdTranslator - Improve material handling on building shading surfaces
  • Improved: #891, Show District Heating and Cooling End-uses in Results Summary Graphs
  • Fixed: #1709, Bug in plant operation schemes object for component setpoint
  • Fixed: #1745, Fix component setpoint scheme

OpenStudio v1.8.2

2015-07-24 — Diff
  • Added: #1674, Add support of heat pump water heater
  • Added: #1682, Add support of WaterHeater:Stratified
  • Improved: #1653, IFC import improvements
  • Fixed: #1489, EPWFile ruby access
  • Fixed: #1733, TimeSeries Fix

OpenStudio v1.8.1

2015-07-14 — Diff
  • Added: #1652 Design days grid view
  • Improved: #1716 New default standard reporting measure
  • Improved: #1458, EPWFile includes new methods to get TimeSeries data from weather files, SWIG bindings to the EPWFile class have been improved
  • Improved: #1440, Integrate openstudio-aws-gem into openstudio
  • Improved: #1698, AWS and Gem Updates
  • Fixed: #1699, Meters are missing time indices in sql file

OpenStudio v1.8.0

2015-06-26 — Diff
  • Added: Allow Gem installation at build time
  • Fixed: #599, Some HVAC components that exist in OpenStudio are missing from the HVAC library
  • Fixed: #1440, Update PAT to use aws-gem for cloud initialization
  • Fixed: #1476, IG Hard Sized / Autosized Behavior
  • Fixed: #1556, Create One With Selected Measures creates design alternative with empty name
  • Fixed: #1573, Some RefrigerationCase defrost options are not supported
  • Fixed: #1605, Error in AirLoopHVACUnitarySystem Library
  • Fixed: #1606, HW Coil in AirTerminalSingleDuctParallelPIUReheat cannot be connected
  • Fixed: #1644, Wrong unit shown for Heat Exchanger U-Factor Times Area Value in OS:HeatExchanger:FluidToFluid
  • Fixed: #1667, SketchUp Inspector does not properly create ThermalZone
  • Fixed: #1673, UnitHeater doesn't allow Fan:OnOff
  • Fixed: #1676, Two HeatExchangerAirToAirSensibleAndLatent are output to EquipmentList
  • Fixed: #1686, Fix error in ThermalZone::clone
  • Fixed: #1687, ThermalZone::remove leaves an orphaned connection
  • Fixed: #1692, TimeSeries timestamps made incorrectly using E+ 8.3 sql file
  • Fixed: #1699, Meters are missing time indices in sql file

OpenStudio v1.7.5

2015-06-01 — Diff
  • Added: #1666, Added HeaderedPumpsConstantSpeed to model
  • Added: #1666, Added HeaderedPumpsVariableSpeed to model
  • Added: #1666, Added TemperingValve to model
  • Added: #1666, Added CoilPerformanceDXCooling to model
  • Added: #1666, Added CoilCoolingDXTwoStageWithHumidityControlMode to model
  • Added: #1666, Added CoilSystemCoolingWaterHeatExchangerAssisted to model
  • Added: #1666, Added GroundHeatExchangerHorizontalTrench to model
  • Added: #1666, Added ThermalStorageIceDetailed to model
  • Added: #1666, Added ChillerAbsorptionIndirect to model
  • Added: #1666, Added ChillerAbsorption to model
  • Changed: #1658, StraightComponent::addToNode will now remove from existing loop first
  • Changed: #1662, WaterHeaterMixed will now be more fully initialized
  • Improved: #1637, DistrictHeating / DistrictCooling ::nominalCapacity is now autosizable
  • Improved: #1638, HumidifierSteamElectric::ratedCapacity is now autosizable
  • Improved: [#1666] ( NREL#1666 ), Enhance SizingSystem with scalable sizing
  • Improved: [#1639] ( NREL#1639 ), Add SizingPlant coincident sizing option
  • Fixed: [#1655] ( NREL#1655 ), SQLFile queries much slower for E+ 8.3 results
  • Fixed: [#1660] ( NREL#1660 ), PAT and OS App helps links are dead
  • Fixed: [#1665] ( NREL#1665 ), OpenStudio OS X Packages are broken
  • Removed: #1648, Removed AirLoopHVAC::addAirLoopComp, please use HVACComponent::addToNode instead

OpenStudio v1.7.4

2015-05-18 — Diff
  • Fixed: #1411, IG should not add a NULL choice to the lights definition combo box.

OpenStudio v1.7.3

2015-04-29 — Diff
  • Added: [#1631] ( NREL#1631 ) Added new method OpenStudio::getEnergyPlusExecutable which can be used to determine the location of the EnergyPlus installation included in OpenStudio.
  • Fixed: #1580, Fixed errors in which OpenStudio could not be used on a system without a graphics adapter.
  • Fixed: #1580, Evap cooler 1.7.1 -> 1.7.2 version translation error

OpenStudio v1.7.2

2015-04-21 — Diff
  • Added: #1624, Support for EnergyPlus 8.3
  • Improved: #1621, EvaporativeCoolerDirectResearchSpecial::RecirculatingWaterPumpPowerConsumption is now autosizable
  • Improved: #1623, EvaporativeCoolerIndirectResearchSpecial::RecirculatingWaterPumpPowerConsumption is now autosizable
  • Fixed: #1594, RadianceParameters coarse and fine value adjustments
  • Fixed: #1620, Building shading surfaces exported incorrectly in RadFwdTrans

OpenStudio v1.7.1

2015-03-31 — Diff

OpenStudio v1.7.0

2015-03-27 — Diff
  • Added: #1524, Download VRF components from BCL and use in OpenStudio Application
  • Changed: #1521, ZoneHVACComponent coils should stay attached to plant when cloning into same model
  • Changed: #1510, ExteriorLights::schedule now returns boost::optional instead of Schedule
  • Fixed: #485, Radiance ForwardTranslator crashes if interior partitions missing construction
  • Fixed: #667, User should not be able to change space shading to building shading in inspector
  • Fixed: #883, E+ translator warning: Unknown object OS:ClimateZones
  • Fixed: #1297, Exterior lights crash on tranlastion to idf
  • Fixed: #1299, Matched surface error if one space is not translated
  • Fixed: #1340, Opening a previously run PAT project in a new OS version deletes all of the results
  • Fixed: #1346, Results lost on model re-open - "Error opening measure and run data"
  • Fixed: #1348, Arguments for E+ measures gets empty workspace in app
  • Fixed: #1363, 1.6.0 PAT crash when switching to results tab
  • Fixed: #1364, 1.6.0 PAT crash when run then cancel a simulation
  • Fixed: #1376, PAT export to spreadsheet broken
  • Fixed: #1461, Sql.annualTotalUtilityCost and .annualTotalCost methods incorrect when district heating or cooling
  • Fixed: #1481, Infinite directories for OSM in measure directory
  • Fixed: #1506, GridView column headings are sometimes clipped
  • Fixed: #1507, Unused resource objects not purged from input models to RadianceForwardTranslator
  • Fixed: #1509, ZoneHVACComponent::clone
  • Fixed: #1518, ResultsViewer bugs from QWT update
  • Fixed: #1523, TableMultiVariableLookup not translating correctly
  • Fixed: #1539, Window reveals are incorrect

OpenStudio v1.6.3

2015-03-10 — Diff
  • Added: #1505, Added multi-edit capability to grid views in OpenStudio Application
  • Improved: #1513, Partitioning and triangulation of surfaces with doors
  • Improved: #1488, Better IDF import log messages
  • Improved: #1486, Switching to QWebEngine if building with Qt >= 5.4
  • Fixed: #318, Daylighting results only applied to 1 zone out of 9
  • Fixed: #447, User model crashes when trying to add thermal zone to air loop named "Gas Fired Furnace"
  • Fixed: #641, Orphan Controller:MechanicalVentilation object
  • Fixed: #870, Cloning object from library multiple times will keep making extra copies in the model
  • Fixed: #978, Cloning Building doesn't bring over thermostatSetpointDualSetpoint
  • Fixed: #980, Clone Building doesn't keep spaces connected to thermal zones
  • Fixed: #1296, Schedule causes crash on translation to IDF
  • Fixed: #1350, Repeatable way to have walls fly away when adding fenestration in Plugin
  • Fixed: #1357, SPM Mixed Air Magic Fails on AirLoops with Unitary Equipment
  • Fixed: #1372, PAT Crash when any measure fails because of a ruby error
  • Fixed: #1378, Crash when running user file
  • Fixed: #1482, Define New Schedule dialog isn't modal, can get lost behind app.
  • Fixed: #1495, Shading surfaces not imported from gbXML
  • Removed: #1499, Removed FloodPlot, LinePlot, AnnotatedTimeline, Barchart, and PieChart classes. These have been deprecated in favor of JavaScript reporting measures.
2015-02-19 — Diff
  • Added: #1418, New fan coils and cycling PTAC for the library
  • Added: #1457, Window frame and divider object
  • Added: #1457, Added support for wall thickness in Radiance, translating WindowFrameAndDivider objects to impostor geometry
  • Added: #1503, Radiance 3-phase simulation for dynamic window shading controls
  • Improved: #1377, Testing around implementation of clone
  • Fixed: #486, ModelToRadPreProcess changes GlassDoor to regular Door
  • Fixed: #1380, Crash when manually disconnecting CoilHeatingWater from loop
  • Fixed: #1413, Unparented widget flash on selected in grid view
  • Fixed: #1456, Crash on remove water coil
2015-02-09 — Diff
  • Added: #1356, Support for TransOption in SDD ReverseTranslator
  • Added: #1367, AirLoopHVAC::supplyFan, AirLoopHVAC::returnFan, AirLoopHVAC::reliefFan. These DO NOT account for fans inside compound objects like unitary systems.
  • Improved: #1374, Implementation of thermal zone clone
  • Improved: #1463, Schedule editor GUI updates in OpenStudio Application including ability to copy schedules
  • Improved: #1367, Setpoint manager logic so that fans inside unitary systems are accounted for. This is done during OS -> IDF translation.
  • Fixed: #7, A number of Simulation Settings Tab fields should be OSComboBoxes rather than OSLineEdits
  • Fixed: #645, PAT tab 4 - mouse over to see measures doesn't work in calibration mode
  • Fixed: #1291, OutputControl:ReportingTolerances not SWIGd