The amount of time(in seconds) to delay logging an error against the fan when any of its sensors are deemed nonfunctional. This attribute is optional and defaults to no error being logged when the attribute is not given and a sensor is nonfunctional.
Note: The default of this changes to 0(immediately log an error) if the
fault_handling
section of the configuration is given.
integer (default = do not create an error log)
{
"fans": [
{
"inventory": "/system/chassis/motherboard/fan0",
"allowed_out_of_range_time": 30,
"functional_delay": 5,
"deviation": 15,
"num_sensors_nonfunc_for_fan_nonfunc": 1,
"monitor_start_delay": 30,
"fan_missing_error_delay": 20,
"nonfunc_rotor_error_delay": 0,
"sensors": [
{
"name": "fan0_0",
"has_target": true
},
{
"name": "fan0_1",
"has_target": false,
"factor": 1.45,
"offset": -909
}
]
}
]
}