Skip to content

Latest commit

 

History

History
24 lines (17 loc) · 709 Bytes

README.md

File metadata and controls

24 lines (17 loc) · 709 Bytes

gaposa-linkit-RS232

A simple script communicate with the Gaposa LinkIt RS-232

The documentation for the unit can be found as links from https://www.gaposa.it/eng/linkit/

Example output:

Instructions: [103, 0, 1, 238, 136]
Checksum: 136
Binary Data: b'g\x00\x01\xee\x88'
Response: b''

To help with the debugging, set up a virtual port:

socat -x -v /dev/ttyS0,rawer,b9600,crnl PTY,link=/tmp/ttyV1,rawer,crnl

Socat output will look like:

< 2023/01/13 22:42:55.539238  length=5 from=0 to=4
 67 00 01 ee 88                                   g....
--
< 2023/01/13 22:44:09.596044  length=5 from=5 to=9
 67 00 01 aa cc                                   g....
--