ada2fhir: multiple ada instances which could contained 'reversed references' lead to unexpected results #216

Open
jd-nictiz opened this issue Dec 17, 2021 · 0 comments
Assignees

Comments

@jd-nictiz
Copy link
Contributor

jd-nictiz commented Dec 17, 2021

When X ada instances (for example FunctionalOrMentalStatus) contain the exact same MedicalDevice, there could be 2 possible outputs:

  • 1 DeviceUseStatement with X .reasonReferences
  • X DeviceUseStatements with 1 .reasonReference each

At the moment our ada2fhir process always outputs 1 resource with 1 .reasonReference (whichever is processed last), which is wrong anyways. This should change to one of these scenario's. Is there a functional basis for the latter? Or is the first output always needed?

@jd-nictiz jd-nictiz self-assigned this Dec 20, 2021
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment