From 0f9ca6e712662dd2a04f293b79846e06767a32b0 Mon Sep 17 00:00:00 2001 From: rqthomas Date: Thu, 3 Oct 2024 11:11:47 -0400 Subject: [PATCH] fixing O2 units issue --- workflows/glm_aed_flare_v3/combined_run_aed.R | 1 - 1 file changed, 1 deletion(-) diff --git a/workflows/glm_aed_flare_v3/combined_run_aed.R b/workflows/glm_aed_flare_v3/combined_run_aed.R index 60824f9..e798b31 100644 --- a/workflows/glm_aed_flare_v3/combined_run_aed.R +++ b/workflows/glm_aed_flare_v3/combined_run_aed.R @@ -124,7 +124,6 @@ while(noaa_ready & inflow_ready){ variable = ifelse(variable == "Temp_C_mean", "Temp_C_mean_all_depth", variable), variable = ifelse(variable == "temp_mean", "Temp_C_mean", variable), depth_m = ifelse(variable == "Temp_C_mean", 1.6, depth_m), - prediction = ifelse(variable == "DO_mgL_mean", prediction/1000*(32),prediction), prediction = ifelse(variable == "fDOM_QSU_mean", (151.3407 + prediction)/29.62654,prediction), prediction = ifelse(variable == "NIT_amm", prediction/1000/0.001/(1/18.04),prediction), variable = ifelse(variable == "NIT_amm", "NH4_ugL_sample", variable),